PATENT NUMBERS CAN 1.130.426 USA: 4.345.554 - 5.614.883 5.617.819 - 5.673.017 AND OTHER PATENTS PENDING All rights reserved © Astroflex Electronic
8 TOPIC DEFAULT FEATURES FOR STAGE 2 LEVEL Accessory output Relay • Accessory Level 1 Page 23 Parking Light output Relay • Parking Light Level 2 Pa
9 Detailed Description P1: ALARM (OPTIONNAL) P1-1: Red/White: SIREN OUTPUT (+) This output (+12 VDC) is fuse protected (3A fuse) and feeds the siren
10 P1-8: Yellow: ANTI-LOCKING This input is used to detect the presence of the key in the ignition switch in order to cancel locking of the doors duri
11 P2-6: Dark Green: NEGATIVE OUT WHEN RUNNING This (-) output is powered up 1 second before ignition, remains on during run time and remains on 1 s
12 P2-13 to P2-16: PROGRAMMABLE OUTPUT #1 to #4 Negative outputs (-) where the function can be determined in Stage 1 - Level 5 to 8, Page 19. P2-13: B
13 P4-3: Green: PARKING LIGHT OUTPUT This wire provides a positive output to trigger the vehicle's parking light circuit to add a visual confir
14 P6 - P16: CONNECTORS FOR PLUG-IN ACCESSORIES Position and description of the connectors under the access door. P6: SHOCK SENSOR (supplied with alar
15 P11: VALET SWITCH Connector allowing a push-button switch to be plugged into the module to control the “Valet” mode for both the AstroStart alarm
16 Detailed programming of the control module Programming procedure Programming is accomplished using 9 Dipswitches incorporated into the module or a
17 Programming Tables In the following tables, the shaded option is the default setting. DEFAULT SETTING: Normal operation AUTOMATIC TACH LEARN
IMPORTANT NOTICE TO INSTALLERS! The control module included in this kit must be interfaced according to the type of vehicle in which it is in
18 ENGINE CONFIGURATION STAGE 1 - LEVEL 3 5 6 7 8 9 Parking Light Circuit P2-5 (Orange/White) used to monitor Glow Plug *1 15 sec
19 PROGRAMMABLE OUTPUTS 1, 2, 3 & 4 STAGE 1 - LEVEL 5, 6, 7 & 8 DEFAULT LEVEL 5 6 7 8 9 Pulse Before Start (Default Output #1) 5
20 LOCK/UNLOCK OPTIONS STAGE 1 - LEVEL 10 5 6 7 8 9 0.7 sec. Pulse before Ignition duration 0.35 sec. 0.7 sec. Door Loc
21 DURATIONS: UTILITY 1 & 2 & PANIC STAGE 1 - LEVEL 11 5 6 7 8 9 0.7 sec. 15 sec. 1 minute Utility Duration 1 8
22 ALARM STAGE 1 - LEVEL 14 5 6 7 8 9 Alarm Disabled Active Arming Semi-Passive Arming AstroStart Alarm Passive Arm
23 ACCESSORY & PARKING LIGHT RELAY STAGE 2 - LEVEL 1 AND 2 DEFAULT LEVEL 5 6 7 8 9 Pulse Before Start Pulse After Shutdown
24 Diagnostic Codes When the module is in operating mode (ready to start), the LED may display different diagnostic codes for troubleshooting. It flas
25 VERIFICATION OF INSTALLATION Make sure that the module is set to desired mode, Automatic Transmission or Manual Transmission , at Stage 1 - L
26 POST-INSTALLATION AND SECURITY TESTS When installation is complete, check all safety devices. Make sure that the engine does not start or that it
27 CODE LEARNING OF TRANSMITTER (S) ALL REMOTES INCLUDED IN ASTROSTART REMOTE STARTER KITS ARE FACTORY PROGRAMMED. THERE IS NO NEED TO PROGRAM THEM
1 Table of contents VERIFICATIONS AND TESTING TO BE DONE BEFORE THE INSTALLATION... 2 QUICK GUID
28
2 VERIFICATIONS AND TESTING TO BE DONE BEFORE THE INSTALLATION To ensure that the installation and the use of this product are safe, you must fo
3 Quick Guide for Skilled Installers This section of the installation manual is intended for experienced installers of remote starter and mobile secu
4 DESCRIPTION OF CONNECTORS The following charts show the purpose of each wire on each connector and list the pin position, color code and give a brie
5 P2 CONNECTOR PIN COLOR DESCRIPTION PURPOSE 6 Dark Green Ground when running Output (-) 150ma max Connect this wire to a circuit that requires a
6 P4 CONNECTOR PIN COLOR DESCRPTION PURPOSE 1 Red/Black Power Input +12V power input, protected by a 30A fuse (F1) Supplies "Accessory-Yellow
7 Default Setting You may believe that a product as versatile as this one would be a programming nightmare. In most cases, you will not need to chang