AstroStart 701U Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Auto Alarmanlage AstroStart 701U herunter. AstroStart 701U Installation manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 30
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
PATENT NUMBERS
CAN 1.130.426
USA: 4.345.554 - 5.614.883
5.617.819 - 5.673.017
AND OTHER PATENTS PE
NDING
All rights reserved
© Astroflex Electronics 2007 August 2007 IBRSS5224
INSTALLATION MANUAL
XRT - BBK - BBF - BBU - BBW
CONTROL MODULES
FOR ALL
GAS, DIESEL
AND HYBRID
POWERED VEHICLES
(Instructions en français au verso)
REMOTE CONTROL
ENGINE STARTER
THIS PRODUCT MUST BE INSTALLED
BY A QUALIFIED INSTALLER.
When this product is installed in a manual transmission vehicle,
the installation must be done with a manual interface
(not included - No. RS-MI).
Seitenansicht 0
1 2 3 4 5 6 ... 29 30

Inhaltsverzeichnis

Seite 1 - ENGINE STARTER

PATENT NUMBERS CAN 1.130.426 USA: 4.345.554 - 5.614.883 5.617.819 - 5.673.017 AND OTHER PATENTS PENDING All rights reserved © Astroflex Electronic

Seite 2

8 TOPIC DEFAULT FEATURES FOR STAGE 2 LEVEL Accessory output Relay • Accessory Level 1 Page 23 Parking Light output Relay • Parking Light Level 2 Pa

Seite 3 - Table of contents

9 Detailed Description P1: ALARM (OPTIONNAL) P1-1: Red/White: SIREN OUTPUT (+) This output (+12 VDC) is fuse protected (3A fuse) and feeds the siren

Seite 4 - BEFORE THE INSTALLATION

10 P1-8: Yellow: ANTI-LOCKING This input is used to detect the presence of the key in the ignition switch in order to cancel locking of the doors duri

Seite 5

11 P2-6: Dark Green: NEGATIVE OUT WHEN RUNNING This (-) output is powered up 1 second before ignition, remains on during run time and remains on 1 s

Seite 6 - DESCRIPTION OF CONNECTORS

12 P2-13 to P2-16: PROGRAMMABLE OUTPUT #1 to #4 Negative outputs (-) where the function can be determined in Stage 1 - Level 5 to 8, Page 19. P2-13: B

Seite 7

13 P4-3: Green: PARKING LIGHT OUTPUT This wire provides a positive output to trigger the vehicle's parking light circuit to add a visual confir

Seite 8

14 P6 - P16: CONNECTORS FOR PLUG-IN ACCESSORIES Position and description of the connectors under the access door. P6: SHOCK SENSOR (supplied with alar

Seite 9 - Default Setting

15 P11: VALET SWITCH Connector allowing a push-button switch to be plugged into the module to control the “Valet” mode for both the AstroStart alarm

Seite 10 - CONTROL MODULE PROGRAMMING

16 Detailed programming of the control module Programming procedure Programming is accomplished using 9 Dipswitches incorporated into the module or a

Seite 11 - Detailed Description

17 Programming Tables In the following tables, the shaded option is the default setting. DEFAULT SETTING: Normal operation AUTOMATIC TACH LEARN

Seite 12 - P2: INPUT/OUTPUT

IMPORTANT NOTICE TO INSTALLERS! The control module included in this kit must be interfaced according to the type of vehicle in which it is in

Seite 13

18 ENGINE CONFIGURATION STAGE 1 - LEVEL 3 5 6 7 8 9 Parking Light  Circuit P2-5 (Orange/White) used to monitor Glow Plug *1  15 sec

Seite 14 - P4: MAIN HARNESS

19 PROGRAMMABLE OUTPUTS 1, 2, 3 & 4 STAGE 1 - LEVEL 5, 6, 7 & 8 DEFAULT LEVEL 5 6 7 8 9 Pulse Before Start (Default Output #1) 5     

Seite 15 - P5: PROGRAMMABLE RELAY

20 LOCK/UNLOCK OPTIONS STAGE 1 - LEVEL 10 5 6 7 8 9 0.7 sec.  Pulse before Ignition duration 0.35 sec.  0.7 sec.  Door Loc

Seite 16 - HITE – TRIGGER INPUT

21 DURATIONS: UTILITY 1 & 2 & PANIC STAGE 1 - LEVEL 11 5 6 7 8 9 0.7 sec.   15 sec.   1 minute   Utility Duration 1 8

Seite 17

22 ALARM STAGE 1 - LEVEL 14 5 6 7 8 9 Alarm Disabled   Active Arming   Semi-Passive Arming   AstroStart Alarm Passive Arm

Seite 18 - Programming procedure

23 ACCESSORY & PARKING LIGHT RELAY STAGE 2 - LEVEL 1 AND 2 DEFAULT LEVEL 5 6 7 8 9 Pulse Before Start      Pulse After Shutdown    

Seite 19 - Programming Tables

24 Diagnostic Codes When the module is in operating mode (ready to start), the LED may display different diagnostic codes for troubleshooting. It flas

Seite 20

25 VERIFICATION OF INSTALLATION Make sure that the module is set to desired mode, Automatic Transmission or Manual Transmission , at Stage 1 - L

Seite 21

26 POST-INSTALLATION AND SECURITY TESTS When installation is complete, check all safety devices. Make sure that the engine does not start or that it

Seite 22 - CONTROL UNIT

27 CODE LEARNING OF TRANSMITTER (S) ALL REMOTES INCLUDED IN ASTROSTART REMOTE STARTER KITS ARE FACTORY PROGRAMMED. THERE IS NO NEED TO PROGRAM THEM

Seite 23

1 Table of contents VERIFICATIONS AND TESTING TO BE DONE BEFORE THE INSTALLATION... 2 QUICK GUID

Seite 25 - STAGE 2

2 VERIFICATIONS AND TESTING TO BE DONE BEFORE THE INSTALLATION To ensure that the installation and the use of this product are safe, you must fo

Seite 26 - Diagnostic Codes

3 Quick Guide for Skilled Installers This section of the installation manual is intended for experienced installers of remote starter and mobile secu

Seite 27 - STEP 2: FULL START TEST

4 DESCRIPTION OF CONNECTORS The following charts show the purpose of each wire on each connector and list the pin position, color code and give a brie

Seite 28

5 P2 CONNECTOR PIN COLOR DESCRIPTION PURPOSE 6 Dark Green Ground when running Output (-) 150ma max Connect this wire to a circuit that requires a

Seite 29 - ITH THE IGNITION KEY

6 P4 CONNECTOR PIN COLOR DESCRPTION PURPOSE 1 Red/Black Power Input +12V power input, protected by a 30A fuse (F1) Supplies "Accessory-Yellow

Seite 30

7 Default Setting You may believe that a product as versatile as this one would be a programming nightmare. In most cases, you will not need to chang

Kommentare zu diesen Handbüchern